EcoStruxure Machine Expert - HVAC v1.0 Release Notes

Preparing to load PDF file. please wait...

0 of 0
100%
EcoStruxure Machine Expert - HVAC v1.0 Release Notes

Transcript Of EcoStruxure Machine Expert - HVAC v1.0 Release Notes

EcoStruxure Machine Expert - HVAC v1.0

Release Notes

Software / Firmware Version:
TM171PDM27
TM171PBM27R
TM171PFE03
TM171DGRP TM172P28/ TM172P42 TM172O28/ TM172P42 TM172P07/ TM172P18/ TM172O07/ TM172P18 TM172DCLW/TM172DCLF
TM171O TM171SW (EcoStruxure Machine Expert - HVAC)

Firmware msk: 423.27 Firmware msk: 477.27 Firmware msk: 489.20 Firmware msk: 476.20 Firmware msk: 596.08
Firmware msk: 668.08 Firmware msk: 659.05 Firmware msk: 542.09 v 1.0.0

This document contains important information about the EcoStruxure Machine Expert - HVAC software. Please read the complete document before you run the product.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. All pertinent state, regional, and local safety regulations must be observed when installing and using this product. When devices are used for applications with technical safety requirements, the relevant instructions must be followed. Failure to use Schneider Electric software or approved software with our hardware products may result in injury, harm, or improper operating results. Failure to observe this information can result in injury or equipment damage. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us. No part of this document may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express written permission of Schneider Electric.
Copyright © September 2018 – Schneider Electric. All rights reserved.

1 / 21 Release Notes - EcoStruxure Macine Expert - HVAC v1.0 | Schneider Electric

Table of Contents
1. System Requirements ................................................................................................................... 3 2. Important information .................................................................................................................... 4 3. New features in EcoStruxure Machine Expert - HVAC v1.0.0 ...................................................... 5 4. New features in TM172P/TM172O (Firmware msk 596.08 and msk 668.08) 6 5. New features in TM172DCL (Firmware msk 659.05)............................................................ 7 6. New features in TM171PFE03 (Firmware msk 489.20) .......................................................... 8 7. New features in TM171DGRP (Firmware msk 476.20) ................................................................ 9 8. New features in TM171PDM27 (Firmware msk 423.27) .......................................................... 10 9. New features in TM171PBM27R (Firmware msk 477.27) .......................................................... 11 10. New features in TM171O (Firmware msk 542.09) ....................................................... 12 11. Documentation update ................................................................................................................ 13 12. New Features description ........................................................................................................... 14 13. Release history............................................................................................................................ 17
2 / 21 Release Notes - EcoStruxure Macine Expert - HVAC v1.0 | Schneider Electric

1. SYSTEM REQUIREMENTS

Schneider Electric EcoStruxure Machine Expert - HVAC can be installed on a personal computer having the following characteristics: Operative System
• Windows 7 Home Premium 32 Bit & 64 Bit • Windows 7 Professional 32 Bit & 64 Bit • Windows 7 Ultimate 32 Bit & 64 Bit • Windows 8 / 8.1 64 Bit • Windows 10 64 Bit

Hardware requirements • Processor • RAM Memory • Hard Disk • Peripherals • Peripherals • Web access

Pentium 1.6 GHz or greater 1 GB; 2 GB preferred 500 MB of free space Mouse or compatible pointing device USB interface Web registration requires Internet access

Please note the following information from Microsoft:
Windows XP support has ended As of April 8, 2014, support and updates for Windows XP are no longer available.

EcoStruxure Machine Expert - HVAC requires Administrator rights to be installed.

For further information, contact your Schneider Electric support center.

3 / 21 Release Notes - EcoStruxure Macine Expert - HVAC v1.0 | Schneider Electric

2. IMPORTANT INFORMATION
2.1. Provided templates and project examples
********Disclaimer of Warranty********
THE INFORMATION CONTAINED HEREIN, AND WITHIN ANY RELATED SCHNEIDER ELECTRIC DOCUMENTATION, IS PROVIDED "AS IS" WITHOUT WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, NON-INFRINGEMENT OR OTHER VIOLATION OF RIGHTS. SCHNEIDER ELECTRIC DOES NOT WARRANT OR MAKE ANY REPRESENTATIONS REGARDING THE USE, VALIDITY, ACCURACY, OR RELIABILITY OF, OR THE RESULTS OF THE USE OF, OR OTHERWISE, RESPECTING THE MATERIALS, SPECIFICATIONS, CHARACTERISTICS OR OTHER INFORMATION SPECIFIED HEREIN. FURTHERMORE, ALL WARRANTIES, CONDITIONS, REPRESENTATIONS, INDEMNITIES AND GUARANTEES WITH RESPECT TO THE ACCURACY, OPERATION, CAPACITY, SPEED, FUNCTIONALITY, QUALIFICATIONS, OR CAPABILITIES OF THE SOFTWARE, SYSTEMS AND SERVICES COMPRISING OR UTILIZED IN THE COURSE OF APPLYING THIS INFORMATION, SPECIFICATIONS, OR MATERIALS, WHETHER EXPRESS OR IMPLIED, ARISING BY LAW, CUSTOM, PRIOR ORAL OR WRITTEN STATEMENTS BY SCHNEIDER ELECTRIC, OR OTHERWISE (INCLUDING, BUT NOT LIMITED TO ANY WARRANTY OF SATISFACTORY QUALITY, MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, TITLE AND NON-INFRINGEMENT) ARE HEREBY EXPRESSLY EXCLUDED AND DISCLAIMED.
********Disclaimer of Liability*********
UNDER NO CIRCUMSTANCES (INCLUDING NEGLIGENCE OR FORESEEABLE MISUSE) WILL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES (INCLUDING WITHOUT LIMITATION, BUSINESS INTERRUPTION, DELAYS, LOSS OF DATA OR PROFIT) ARISING OUT OF THE APPLICATION OF THE INFORMATION, SPECIFICATIONS, CHARACTERISTICS OR MATERIALS CONTAINED HEREIN EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
************************************
The information, program and configuration contained herein, as in other Schneider Electric documentation, are provided as general training on the products concerned, in part, by way of theoretical and/or hypothetical examples. Only you, the user, can be aware of all the conditions and factors present during setup, operation, and maintenance of your machine and its application; therefore, only you, the user, can determine the automation equipment and the related safeties and interlocks which can be properly used. When selecting automation and control equipment and related software for a particular application, you must refer to the applicable local and national standards and regulations.
************************************
Copyright © September 2018 – Schneider Electric. All rights reserved.
4 / 21 Release Notes - EcoStruxure Macine Expert - HVAC v1.0 | Schneider Electric

3. NEW FEATURES IN ECOSTRUXURE MACHINE EXPERT - HVAC V1.0.0
The following new features are in comparison with SoMachine HVAC 2.4:
• Improvements and rebranding of the software: EcoStruxure Machine Expert – HVAC o Renewed layout and ‘look and feel’, aligned with EcoStruxure guidelines o Improved usability; all operations accessible from one executable program o Improved functionalities o Improved documentation
• New online help: o Integration of all documents related to software, libraries, hardware and TVDAs o Improved features with documents in HTML format and search function o New Software Operating Guide
• Availability of new TVDA, in addition to four already available in SoMachine HVAC V2.4: o Air-water Heat Pump for Large and Connected Machines (Source code, Electrical Diagram and User Guide available inside Software)
• Availability of seven new AFBs: o Circuit Management: CircuitMgmt o Evaporator Pressure Control: EvapPressCntrl o Floating Water Temperature Setpoint: FloatingWaterTempSet o Heat Pump Defrost Circuit Priority: HPDefrCircuitPriority o Heat Pump Defrost and Reversing: HPDefrostAndRevValve o Mode Selection: ModeSelection o Quick Response Code Bitmap Generator and Display: QRCodeGenDisplay o (User Guide available inside Software)
5 / 21 Release Notes - EcoStruxure Macine Expert - HVAC v1.0 | Schneider Electric

4. NEW FEATURES IN TM172P/TM172O (FIRMWARE MSK 596.08 AND MSK 668.08)
• Export of PARAM.BIN file with the full image of the not-volatile memory (including BACnet parameters)
• Introduced target function sysFTP_ProtectFiles() to protect filesystem files from read and write operations
• Added management of BINDIN.PAR system file • Added Modbus registers related to current Ethernet settings: IP address, Default gateway, Net
Mask, Primary DNS address and Secondary DNS address • Introduced target function sysMbSTcp_SocketServerInfo() to monitor number of available and
used server sockets • Modbus Master configured via Configuration Perspective starts only if a PLC application is
present and running • New features of target functions sysUART_getbuff(), sysUART_putbuff() and sysUART_init().
They can be applied also to RS485-1 and the additional baud rate 4800 b/s is available. • Solved issue with BACnet Intrinsic reporting • Solved issue with sysMbMRTU_FC06(), sysMbMRTU_FC05(), sysMbMRTU_FC15() and
sysMbMRTU_FC16() Modbus Master target functions in case of sending broadcast message • Solved issue with sysMbMRTU_FC01(), sysMbMRTU_FC02(), sysMbMRTU_FC03() and
sysMbMRTU_FC04() Modbus Master target functions in case of sending broadcast message, now returns dedicated error code (19) • Solved issue with IP conflict detection features when BACnet IP stack is used
6 / 21 Release Notes - EcoStruxure Macine Expert - HVAC v1.0 | Schneider Electric

5. NEW FEATURES IN TM172DCL (FIRMWARE MSK 659.05)
• Increased maximum number of edit control objects per page from 20 to 32 • Removed the maximum number for the objects different from edit control • The maximum number of controls for each page is 100 • Implemented the Read of strings via Modbus when the device is configured as Master • Dynamic change of slave address is now allowed • Improved dynamic visibility of overlapped objects • Solved wrong handling of dynamic visibility for buttons
7 / 21 Release Notes - EcoStruxure Macine Expert - HVAC v1.0 | Schneider Electric

6. NEW FEATURES IN TM171PFE03 (FIRMWARE MSK 489.20)
• Added management of BINDIN.PAR system file • Modbus Master configured via Configuration Perspective starts only if a PLC application is
present and running • New value for Buzzer_Mode parameter: Value 2 links buzzer status to red LED status • Capability to disable Ethernet communication by setting the last three MAC address octets
to 0 • Controller sends PDO related to its probes on CAN line if its CAN address is 126 or 127 and
CONNEC.PAR file does not configure CAN channel (CAN not configured from Configuration Perspective) • Solved issue with BACnet Intrinsic reporting
8 / 21 Release Notes - EcoStruxure Macine Expert - HVAC v1.0 | Schneider Electric

7. NEW FEATURES IN TM171DGRP (FIRMWARE MSK 476.20)
• New value for Buzzer_Mode parameter: Value 2 links buzzer status to red LED status
9 / 21 Release Notes - EcoStruxure Macine Expert - HVAC v1.0 | Schneider Electric

8. NEW FEATURES IN TM171PDM27 (FIRMWARE MSK 423.27)
• Added management of BINDIN.PAR system file • Modbus Master configured via Configuration Perspective starts only if a PLC application is
present and running • Solved issue with BACnet Intrinsic reporting
10 / 21 Release Notes - EcoStruxure Macine Expert - HVAC v1.0 | Schneider Electric
FeaturesEcostruxure Macine ExpertSchneiderSoftwareEcostruxure Machine Expert